Power source OC600
including on-board wire feed unit WF4
The power source with maximum spray current of 600 A (at 100% duty cycle) is convincing with
- its enormous power for coating large areas within a short time
- its compact and robust construction
- the easy handling with good readable indicators
- the clear layout of control elements on the angled panel
- big castors and fixed castors which guarantee easy maneuverability even on the rough terrain of construction sites
- optimized power connectors for high energy efficiency
- the configuration with the feed gear WF4, which ensures together with the proven rubber roller system, a continuous, trouble-free wire feed
Control procedures
The control procedures at start and stop as well as while the spray process work automatically via the preset Siemens-PLC. For example at overload or pressure drop the equipment switches off automatically. The power supply is preset to highest melting capacity but can be adjusted stepless to lower power.
Technical data
Mains voltage | 3 x 400 V AC |
Mains voltage tolerance | ±5 % |
Mains frequency | 50/60 Hz |
Connection current | < 34,6 A |
Main fuse | 63 A |
Connection power | < 24 kVA |
Spray current max. (at 100 % ED) | 600 A DC |
Open-circuit voltage | 26 – 39 V DC |
Spray voltage | 22 – 34 V DC |
Spray wires and deposition rates (at 600 A) | Zn 60,0 kg/h ZnAl 53,0 kg/h Al 18,0 kg/h AlMg 16,0 kg/h |